ADSS Optical Cables Short Span
Fiber reinforced plastic central strength member, Loose tube stranded, PE sheath all-dielectric, Self-supporting aerial cable.

Performance
Application
The actual status of overhead power lines
Operating Temperature
-40℃~+70℃Technical Specification
Fiber Count
Nominal
Nominal
Max Fibers
No. of
Allowable Tensile Load(N)
Allowable Crush Resistance
Diameter(mm)
Weight(kg/km)
per Tube
(Tubes +Fillers)
(N/100mm)
Short Term
Long Term
Short Term
Long Term
2~36
10.7
92
6
6
2700
1000
1000
300
38~72
11.6
103
12
6
2700
1000
1000
300
74~96
13.3
149
12
8
2700
1000
1000
300
98~120
14.8
180
12
10
2700
1000
1000
300
122~144
16.4
222
12
12
2700
1000
1000
300
146~216
18.8
224
12
18(2layers)
2700
1000
1000
300
>216
Available upon customer's request
Note:
The cable technology parameters and fiber count, weather, span can be designed according to the project's requirement.
For the actual status of overhead power lines and he load on pole and towers suspension point. AT outer sheath is applied.
Span no longer than 200m.
*Customized cable structure is available.
ADSS Optical Cables Long Span
Fiber reinforced plastic central strength member, loose tube stranded, PE sheath all-dielectric, self-supporting aerial cable.

Performance
Application
The actual status of overhead power lines
Operating Temperature
-40℃~+70℃Technical Specification
Fiber Count
Nominal
Nominal
Max Fibers
No. of
Allowable Tensile Load(N)
Allowable Crush Resistance
Diameter(mm)
weight(kg/km)
per Tube
(Tubes +Fillers)
(N/100mm)
Short Term
Long Term
Short Term
Long Term
2~36
10.7
92
6
6
2700
1000
1000
300
38~72
11.6
103
12
6
2700
1000
1000
300
74~96
13.3
149
12
8
2700
1000
1000
300
98~120
14.8
180
12
10
2700
1000
1000
300
122~144
16.4
222
12
12
2700
1000
1000
300
146~216
18.8
224
12
18(2layers)
2700
1000
1000
300
>216
Available upon customer's request
Note:
The cable technology parameters and fiber count, weather, span can be designed according to the project's requirement.
For the actual status of overhead power lines and he load on pole and towers suspension point. AT outer sheath is applied.
Large span lengths and the largest span is over 1200m.
*Customized cable structure is available.
Product inquiry
Have a question about purchasing a product or solution that you are interested in? Fill in the form and we’ll respond in 7 working days.
Latest Products