undefined
undefined
+
  • undefined
  • undefined

ADSS Optical Cables

Focused on providing fiber optic communication equipment and supporting products to global customers

  • Description
  • ADSS Optical Cables     Short Span


    Fiber reinforced plastic central strength member, Loose tube stranded, PE sheath all-dielectric, Self-supporting aerial cable.

     

     


     

    Performance 

    Application
    The actual status of overhead power lines
    Operating Temperature
    -40
    ℃~+70℃

    Technical Specification

    Fiber Count

    Nominal

    Nominal

    Max Fibers

    No. of

    Allowable Tensile Load(N)

    Allowable Crush Resistance

    Diameter(mm)

    Weight(kg/km)

    per Tube

    (Tubes +Fillers)

    (N/100mm)

     

     

     

     

    Short Term

    Long Term

    Short Term

    Long Term

    2~36

    10.7

    92

    6

    6

    2700

    1000

    1000

    300

    38~72

    11.6

    103

    12

    6

    2700

    1000

    1000

    300

    74~96

    13.3

    149

    12

    8

    2700

    1000

    1000

    300

    98~120

    14.8

    180

    12

    10

    2700

    1000

    1000

    300

    122~144

    16.4

    222

    12

    12

    2700

    1000

    1000

    300

    146~216

    18.8

    224

    12

    18(2layers)

    2700

    1000

    1000

    300

    >216

    Available upon customer's request

    Note:

    The cable technology parameters and fiber count, weather, span can be designed according to the project's requirement.

    For the actual status of overhead power lines and he load on pole and towers suspension point. AT outer sheath is applied.

    Span no longer than 200m.

    *Customized cable structure is available.

     

     

     

    ADSS Optical Cables     Long Span


    Fiber reinforced plastic central strength member, loose tube stranded, PE sheath all-dielectric, self-supporting aerial cable.

     


     

    Performance 

    Application
    The actual status of overhead power lines
    Operating Temperature
    -40
    ℃~+70℃

    Technical Specification

    Fiber Count

    Nominal

    Nominal

    Max Fibers

    No. of

    Allowable Tensile Load(N)

    Allowable Crush Resistance

    Diameter(mm)

    weight(kg/km)

    per Tube

    (Tubes +Fillers)

    (N/100mm)

     

     

     

     

    Short Term

    Long Term

    Short Term

    Long Term

    2~36

    10.7

    92

    6

    6

    2700

    1000

    1000

    300

    38~72

    11.6

    103

    12

    6

    2700

    1000

    1000

    300

    74~96

    13.3

    149

    12

    8

    2700

    1000

    1000

    300

    98~120

    14.8

    180

    12

    10

    2700

    1000

    1000

    300

    122~144

    16.4

    222

    12

    12

    2700

    1000

    1000

    300

    146~216

    18.8

    224

    12

    18(2layers)

    2700

    1000

    1000

    300

    >216

    Available upon customer's request

    Note:

    The cable technology parameters and fiber count, weather, span can be designed according to the project's requirement.

    For the actual status of overhead power lines and he load on pole and towers suspension point. AT outer sheath is applied.

    Large span lengths and the largest span is over 1200m.

    *Customized cable structure is available.

     


Product inquiry

Have a question about purchasing a product or solution that you are interested in? Fill in the form and we’ll respond in 7 working days.

Submit

Latest Products